{"id":1444,"date":"2026-10-27T16:50:16","date_gmt":"2026-10-27T08:50:16","guid":{"rendered":"https:\/\/powershine-newenergy.com\/?page_id=1444"},"modified":"2026-10-27T20:08:42","modified_gmt":"2026-10-27T12:08:42","slug":"ps-si-d-12kw-48v-ip66-three-phase-hybrid-inverter","status":"publish","type":"page","link":"https:\/\/powershine-newenergy.com\/es\/ps-si-d-12kw-48v-ip66-three-phase-hybrid-inverter\/","title":{"rendered":"European Standard Three-Phase Low-Voltage Hybrid Solar Inverter 12kW 48V IP66 | PS-SI-D-12K"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"1444\" class=\"elementor elementor-1444\">\n\t\t\t\t<div class=\"elementor-element elementor-element-0668755 e-con e-atomic-element e-flexbox-base e-default-div e-1e8821f\" data-id=\"0668755\" data-element_type=\"e-flexbox\" data-e-type=\"e-flexbox\" data-interaction-id=\"0668755\">\n    <div class=\"elementor-element elementor-element-79a0864 e-con e-atomic-element e-flexbox-base e-default-div e-ebae990\" data-id=\"79a0864\" data-element_type=\"e-flexbox\" data-e-type=\"e-flexbox\" data-interaction-id=\"79a0864\">\n    \t\t\t<img fetchpriority=\"high\" decoding=\"async\" class=\"e-image-base e-default-img e-4ece529-2e5b4af\" data-interaction-id=\"4ece529\" id=\"945\" src=\"https:\/\/powershine-newenergy.com\/wp-content\/uploads\/2026\/10\/Three-phase-low-voltage-hybrid-inverter.png\" width=\"1064\" height=\"1478\" srcset=\"https:\/\/powershine-newenergy.com\/wp-content\/uploads\/2026\/10\/Three-phase-low-voltage-hybrid-inverter.png 1064w, https:\/\/powershine-newenergy.com\/wp-content\/uploads\/2026\/10\/Three-phase-low-voltage-hybrid-inverter-216x300.png 216w, https:\/\/powershine-newenergy.com\/wp-content\/uploads\/2026\/10\/Three-phase-low-voltage-hybrid-inverter-737x1024.png 737w, https:\/\/powershine-newenergy.com\/wp-content\/uploads\/2026\/10\/Three-phase-low-voltage-hybrid-inverter-768x1067.png 768w\" alt=\"POWERSHINE PS-SI-D-12K 12kW 48V IP66 European Standard Three-Phase Low-Voltage Hybrid Solar Inverter\"\/>\t\t\n<\/div>\n<div class=\"elementor-element elementor-element-4bd30ae e-con e-atomic-element e-flexbox-base e-default-div e-d9a8b61\" data-id=\"4bd30ae\" data-element_type=\"e-flexbox\" data-e-type=\"e-flexbox\" data-interaction-id=\"4bd30ae\">\n    \t\t\t<h2 data-interaction-id=\"6445822\" class=\"e-6445822-d874040 e-heading-base e-default-h2\">European Standard Three-Phase Low-Voltage Hybrid Solar Inverter<\/h2>\n\t\t\t\t\t<h3 data-interaction-id=\"b32e445\" class=\"e-b32e445-461fad1 e-heading-base e-default-h3\">12kW | Three-Phase 380\/400V AC | 48V DC | PS-SI-D-12K | IP66<\/h3>\n\t\t\t\t\t<p class=\"e-f0d448b-43ca0f1 e-paragraph-base e-default-p\" data-interaction-id=\"f0d448b\">The POWERSHINE PS-SI-D-12K is a high-performance 12kW European Standard Three-Phase Low-Voltage Hybrid Solar Inverter designed for residential and small commercial energy storage applications. Featuring a 48V low-voltage battery system, 380\/400V three-phase AC output, dual MPPT solar inputs, and up to 15kW maximum PV input power, it provides efficient solar energy conversion and flexible energy management.With support for unbalanced three-phase loads, up to 250A battery charging and discharging current, and IP66 protection, the PS-SI-D-12K is suitable for applications requiring reliable power distribution across three phases. Its hybrid design integrates solar PV, battery storage, grid power, and compatible generator input, supporting both on-grid operation and off-grid backup power.The inverter also supports parallel operation of up to 6 units, allowing system capacity expansion for larger residential properties, commercial buildings, and distributed solar energy storage installations.<\/p>\n\t\t\t\t\t<h3 data-interaction-id=\"4257333\" class=\"e-4257333-55a0b3a e-heading-base e-default-h3\">Key Features<\/h3>\n\t\t\t\t\t<p class=\"e-84590bc-b48b75b e-paragraph-base e-default-p\" data-interaction-id=\"84590bc\">\u2022 12kW Three-Phase Hybrid Output \u2013 Designed for European-standard residential and small commercial three-phase power systems.<br>\u2022 380\/400V Three-Phase AC Output \u2013 Suitable for compatible three-phase electrical distribution networks.<br>\u2022 48V Low-Voltage Battery System \u2013 Integrates with compatible lithium and lead-acid energy storage batteries.<br>\u2022 15kW Maximum PV Input Power \u2013 Supports high-capacity rooftop and distributed solar PV installations.<br>\u2022 Dual MPPT Solar Inputs \u2013 Two independent maximum power point trackers optimize solar energy harvesting from different PV arrays.<br>\u2022 1000V Maximum PV Open-Circuit Voltage \u2013 Enables flexible high-voltage solar string configurations within the specified operating limits.<br>\u2022 200\u2013800V MPPT Operating Range \u2013 Wide solar input voltage range for flexible PV system design.<br>\u2022 Up to 250A Battery Charging Current \u2013 Supports high-current charging for compatible 48V battery systems.<br>\u2022 Up to 250A Battery Discharging Current \u2013 Provides strong battery power support for demanding loads.<br>\u2022 Unbalanced Three-Phase Load Support \u2013 Accommodates different power demands across individual phases within inverter limits.<br>\u2022 On-Grid and Off-Grid Operation \u2013 Supports solar self-consumption, battery storage and backup power applications.<br>\u2022 Generator Input Support \u2013 Allows integration with compatible generators for improved energy supply reliability.<br>\u2022 IP66 Protection Rating \u2013 Dust-tight enclosure with protection against powerful water jets.<br>\u2022 Up to 6 Units in Parallel \u2013 Enables scalable inverter capacity for larger energy storage projects.<br>\u2022 Intelligent Hybrid Energy Management \u2013 Coordinates solar PV, battery storage and grid electricity for flexible power utilization.<br>\u2022 Residential and Small Commercial Applications \u2013 Suitable for villas, offices, retail premises, workshops and distributed energy storage systems.<\/p>\n\t\t\n<\/div>\n\n<\/div>\n<div class=\"elementor-element elementor-element-d5dd60d e-con e-atomic-element e-flexbox-base e-default-div e-8a5ae70\" data-id=\"d5dd60d\" data-element_type=\"e-flexbox\" data-e-type=\"e-flexbox\" data-interaction-id=\"d5dd60d\">\n    \t\t\t<h2 data-interaction-id=\"f7e4354\" class=\"e-f7e4354-fc1e06b e-heading-base e-default-h2\">Technical Specifications<\/h2>\n\t\t\n<\/div>\n<div data-aos=\"fade-up\" class=\"hostinger-elementor-aos elementor-element elementor-element-9196248 e-flex e-con-boxed e-con e-parent\" data-id=\"9196248\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-15c052e elementor-widget elementor-widget-wp-widget-custom_html\" data-id=\"15c052e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"wp-widget-custom_html.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"textwidget custom-html-widget\">\r\n<div style=\"width:100%;margin:16px 0 24px\">\r\n<table style=\"width:100%;border-collapse:collapse;font-family:Arial,sans-serif;font-size:13px;line-height:1.5;color:#263445\">\r\n<colgroup>\r\n<col style=\"width:54%\">\r\n<col style=\"width:46%\">\r\n<\/colgroup>\r\n<thead>\r\n<tr style=\"background:#173b64;color:#ffffff\">\r\n<th style=\"padding:12px 9px;text-align:left;border:1px solid #dce4ec\">Technical Parameter<\/th>\r\n<th style=\"padding:12px 9px;text-align:left;border:1px solid #dce4ec\">PS-SI-D-12K<\/th>\r\n<\/tr>\r\n<\/thead>\r\n<tbody>\r\n\r\n<tr style=\"background:#eaf1f8;color:#173b64;font-weight:bold\">\r\n<td colspan=\"2\" style=\"padding:10px 9px\">Solar PV Input<\/td>\r\n<\/tr>\r\n<tr><td>Maximum PV Input Power<\/td><td>15 kW<\/td><\/tr>\r\n<tr><td>Maximum PV Input Current<\/td><td>36 + 18 A<\/td><\/tr>\r\n<tr><td>Maximum PV Short-Circuit Current<\/td><td>45 + 22.5 A<\/td><\/tr>\r\n<tr><td>Maximum PV Open-Circuit Voltage<\/td><td>1,000 V DC<\/td><\/tr>\r\n<tr><td>MPPT Voltage Range<\/td><td>200\u2013800 V DC<\/td><\/tr>\r\n<tr><td>MPPT Full-Load Voltage Range<\/td><td>350\u2013800 V DC<\/td><\/tr>\r\n\r\n<tr style=\"background:#eaf1f8;color:#173b64;font-weight:bold\">\r\n<td colspan=\"2\" style=\"padding:10px 9px\">Grid Input \/ Output<\/td>\r\n<\/tr>\r\n<tr><td>Rated Input \/ Output Active Power<\/td><td>12 kW<\/td><\/tr>\r\n<tr><td>Maximum Input \/ Output Apparent Power<\/td><td>13.2 kVA<\/td><\/tr>\r\n<tr><td>AC Input \/ Output Voltage<\/td><td>380 \/ 400 V AC (3W+N+PE)<\/td><\/tr>\r\n<tr><td>Rated AC Input \/ Output Current<\/td><td>21 \/ 20 A<\/td><\/tr>\r\n<tr><td>Battery-Mode Overload Capacity<\/td><td>&gt;200% for 10 s<\/td><\/tr>\r\n<tr><td>Grid Frequency Range<\/td><td>50 \/ 60 Hz<\/td><\/tr>\r\n<tr><td>Output Power Factor (Off-Grid)<\/td><td>0.8 Leading to 0.8 Lagging<\/td><\/tr>\r\n<tr><td>Output Current Harmonic Distortion<\/td><td>&lt;3% (Nominal Power)<\/td><\/tr>\r\n<tr><td>Maximum Parallel Quantity<\/td><td>6 Units<\/td><\/tr>\r\n\r\n<tr style=\"background:#eaf1f8;color:#173b64;font-weight:bold\">\r\n<td colspan=\"2\" style=\"padding:10px 9px\">Generator Input<\/td>\r\n<\/tr>\r\n<tr><td>Rated Input \/ Output Active Power<\/td><td>12 kW<\/td><\/tr>\r\n<tr><td>Maximum Input \/ Output Apparent Power<\/td><td>13.2 kVA<\/td><\/tr>\r\n<tr><td>AC Input Voltage<\/td><td>380 \/ 400 V AC (3W+N+PE)<\/td><\/tr>\r\n<tr><td>Rated AC Input Current<\/td><td>20 A<\/td><\/tr>\r\n<tr><td>Input Frequency<\/td><td>50 \/ 60 Hz<\/td><\/tr>\r\n\r\n<tr style=\"background:#eaf1f8;color:#173b64;font-weight:bold\">\r\n<td colspan=\"2\" style=\"padding:10px 9px\">AC Load Output (Standalone)<\/td>\r\n<\/tr>\r\n<tr><td>Rated Output Active Power<\/td><td>12 kW<\/td><\/tr>\r\n<tr><td>Maximum Output Apparent Power<\/td><td>13.2 kVA<\/td><\/tr>\r\n<tr><td>AC Output Voltage<\/td><td>380 \/ 400 V AC (3W+N+PE)<\/td><\/tr>\r\n<tr><td>Rated AC Output Current<\/td><td>20 A<\/td><\/tr>\r\n<tr><td>Output Frequency<\/td><td>50 \/ 60 Hz<\/td><\/tr>\r\n<tr><td>Output Waveform<\/td><td>Pure Sine Wave<\/td><\/tr>\r\n\r\n<tr style=\"background:#eaf1f8;color:#173b64;font-weight:bold\">\r\n<td colspan=\"2\" style=\"padding:10px 9px\">Battery &amp; Charging<\/td>\r\n<\/tr>\r\n<tr><td>Nominal Battery Voltage<\/td><td>48 V DC<\/td><\/tr>\r\n<tr><td>Maximum AC Charging Current<\/td><td>250 A<\/td><\/tr>\r\n<tr><td>Maximum PV Charging Current<\/td><td>250 A<\/td><\/tr>\r\n<tr><td>Maximum Combined PV + AC Charging Current<\/td><td>250 A<\/td><\/tr>\r\n<tr><td>Maximum Battery Discharge Current<\/td><td>250 A<\/td><\/tr>\r\n<tr><td>Battery Operating Voltage Range<\/td><td>43.2\u201358.4 V DC<\/td><\/tr>\r\n\r\n<tr style=\"background:#eaf1f8;color:#173b64;font-weight:bold\">\r\n<td colspan=\"2\" style=\"padding:10px 9px\">Communication &amp; Monitoring<\/td>\r\n<\/tr>\r\n<tr><td>Display<\/td><td>LCD<\/td><\/tr>\r\n<tr><td>Communication Interface<\/td><td>USB<\/td><\/tr>\r\n<tr><td>Optional Remote Monitoring<\/td><td>WiFi \/ 4G<\/td><\/tr>\r\n\r\n<tr style=\"background:#eaf1f8;color:#173b64;font-weight:bold\">\r\n<td colspan=\"2\" style=\"padding:10px 9px\">Environmental Specifications<\/td>\r\n<\/tr>\r\n<tr><td>Ingress Protection<\/td><td>IP66<\/td><\/tr>\r\n<tr><td>Operating Temperature<\/td><td>-10\u00b0C to +55\u00b0C<\/td><\/tr>\r\n<tr><td>Relative Humidity<\/td><td>5\u201395% (Non-condensing)<\/td><\/tr>\r\n<tr><td>Maximum Operating Altitude<\/td><td>4,000 m (Derating above 2,000 m)<\/td><\/tr>\r\n\r\n<tr style=\"background:#eaf1f8;color:#173b64;font-weight:bold\">\r\n<td colspan=\"2\" style=\"padding:10px 9px\">Dimensions &amp; Weight<\/td>\r\n<\/tr>\r\n<tr><td>Product Dimensions (L \u00d7 W \u00d7 H)<\/td><td>658 \u00d7 475 \u00d7 258 mm<\/td><\/tr>\r\n<tr><td>Package Dimensions (L \u00d7 W \u00d7 H)<\/td><td>763 \u00d7 540 \u00d7 370 mm<\/td><\/tr>\r\n<tr><td>Net Weight<\/td><td>38 kg<\/td><\/tr>\r\n<tr><td>Gross Weight<\/td><td>45 kg<\/td><\/tr>\r\n\r\n<tr style=\"background:#eaf1f8;color:#173b64;font-weight:bold\">\r\n<td colspan=\"2\" style=\"padding:10px 9px\">Container Loading<\/td>\r\n<\/tr>\r\n<tr><td>20GP Container<\/td><td>140 Units<\/td><\/tr>\r\n<tr><td>40GP Container<\/td><td>300 Units<\/td><\/tr>\r\n<tr><td>40HQ Container<\/td><td>360 Units<\/td><\/tr>\r\n\r\n<\/tbody>\r\n<\/table>\r\n<\/div>\r\n<\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<h2 data-interaction-id=\"5d709f3\" class=\"e-5d709f3-f57991f e-heading-base e-default-h2\">Applications<\/h2>\n\t\t\t\t\t<p class=\"e-paragraph-base e-default-p\" data-interaction-id=\"88526e3\">\u2022 Three-Phase Residential Solar Energy Storage \u2013 Ideal for villas, large homes, and residential properties equipped with 380\/400V three-phase electrical systems.<br>\u2022 Small Commercial Solar Power Systems \u2013 Suitable for offices, retail stores, restaurants, workshops, and small commercial facilities.<br>\u2022 Unbalanced Three-Phase Load Applications \u2013 Supports installations with different power demands across individual phases, within the inverter's operating limits.<br>\u2022 On-Grid Solar Self-Consumption \u2013 Maximizes the utilization of solar energy to reduce grid electricity consumption and operating costs.<br>\u2022 Off-Grid Three-Phase Power Supply \u2013 Provides independent three-phase electricity for remote properties and facilities with compatible load requirements.<br>\u2022 Three-Phase Backup Power Systems \u2013 Supplies essential electrical loads during grid interruptions through the inverter's standalone AC output.<br>\u2022 Solar PV and 48V Battery Integration \u2013 Combines photovoltaic generation with compatible low-voltage lithium or lead-acid battery storage systems.<br>\u2022 Generator-Assisted Hybrid Energy Systems \u2013 Integrates compatible generators, solar PV, battery storage, and grid power for improved energy reliability.<br>\u2022 Commercial Load Management \u2013 Supports intelligent energy distribution and management for selected commercial electrical loads.<br>\u2022 Distributed Solar Energy Storage Projects \u2013 Suitable for decentralized renewable energy systems requiring three-phase AC output.<br>\u2022 Scalable Hybrid Energy Storage Installations \u2013 Supports parallel operation of up to 6 compatible inverter units for increased system capacity.<br>\u2022 Solar-Powered Workshops and Small Businesses \u2013 Suitable for facilities operating a combination of three-phase equipment and single-phase loads, subject to system sizing and load assessment.<\/p>\n\t\t\t\t\t<h2 data-interaction-id=\"3402823\" class=\"e-3402823-6f6d1c6 e-heading-base e-default-h2\">Solicitar cotizaci\u00f3n<\/h2>\n\t\t\t\t\t<p class=\"e-paragraph-base e-default-p\" data-interaction-id=\"a62c39b\">Interested in the POWERSHINE PS-SI-D-12K 12kW European Standard Three-Phase Low-Voltage Hybrid Solar Inverter? Featuring 380\/400V three-phase AC output, 48V battery compatibility, dual MPPT technology, up to 15kW PV input power, and IP66 protection, this inverter is designed for reliable residential and small commercial solar energy storage applications.<br><br>With support for unbalanced three-phase loads, up to 250A battery charging and discharging current, generator integration, and parallel operation of up to 6 units, the PS-SI-D-12K offers a flexible solution for solar self-consumption, hybrid energy management, and backup power systems.<br><br>Contact POWERSHINE for detailed technical specifications, factory-direct pricing, OEM\/ODM customization, product availability, and bulk order quotations. We welcome cooperation with solar distributors, system integrators, EPC contractors, installers, and renewable energy solution providers worldwide.<\/p>\n\t\t<div data-aos=\"fade-up\" class=\"hostinger-elementor-aos elementor-element elementor-element-0fb610e e-con-full e-flex e-con e-child\" data-id=\"0fb610e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4df4699 elementor-widget elementor-widget-button\" data-id=\"4df4699\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"mailto:marketing@szpowershine.com?subject=Inquiry%20for%20PS-SI-D-12K%2012kW%20Three-Phase%2048V%20IP66%20Hybrid%20Solar%20Inverter\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Email Inquiry<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e1ef2e7 elementor-widget elementor-widget-button\" data-id=\"e1ef2e7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"https:\/\/wa.me\/8618676755973?text=Hello%20POWERSHINE%2C%20I%20am%20interested%20in%20PS-SI-D-12K%2012kW%20Three-Phase%2048V%20IP66%20Hybrid%20Solar%20Inverter.%20Please%20send%20me%20the%20technical%20specifications%20and%20factory%20pricing.\" target=\"_blank\" rel=\"noopener\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">WhatsApp Inquiry<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>European Standard Three-Phase Low-Voltage Hybrid Solar Inverter 12kW | Three-Phase 380\/400V AC | 48V DC | PS-SI-D-12K | IP66 The POWERSHINE PS-SI-D-12K is a high-performance 12kW European Standard Three-Phase Low-Voltage Hybrid Solar Inverter designed for residential and small commercial energy storage applications. Featuring a 48V low-voltage battery system, 380\/400V three-phase AC output, dual MPPT solar [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-1444","page","type-page","status-publish","hentry"],"_hostinger_reach_plugin_has_subscription_block":false,"_hostinger_reach_plugin_is_elementor":false,"_links":{"self":[{"href":"https:\/\/powershine-newenergy.com\/es\/wp-json\/wp\/v2\/pages\/1444","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/powershine-newenergy.com\/es\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/powershine-newenergy.com\/es\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/powershine-newenergy.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/powershine-newenergy.com\/es\/wp-json\/wp\/v2\/comments?post=1444"}],"version-history":[{"count":7,"href":"https:\/\/powershine-newenergy.com\/es\/wp-json\/wp\/v2\/pages\/1444\/revisions"}],"predecessor-version":[{"id":1502,"href":"https:\/\/powershine-newenergy.com\/es\/wp-json\/wp\/v2\/pages\/1444\/revisions\/1502"}],"wp:attachment":[{"href":"https:\/\/powershine-newenergy.com\/es\/wp-json\/wp\/v2\/media?parent=1444"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}