{"id":1541,"date":"2026-10-27T22:25:21","date_gmt":"2026-10-27T14:25:21","guid":{"rendered":"https:\/\/powershine-newenergy.com\/?page_id=1541"},"modified":"2026-10-27T22:27:49","modified_gmt":"2026-10-27T14:27:49","slug":"ps-si-f-12kw-48v-us-standard-split-phase-hybrid-inverter","status":"publish","type":"page","link":"https:\/\/powershine-newenergy.com\/es\/ps-si-f-12kw-48v-us-standard-split-phase-hybrid-inverter\/","title":{"rendered":"US Standard Split-Phase Hybrid Solar Inverter 12kW 48V | PS-SI-F-12K-48"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"1541\" class=\"elementor elementor-1541\">\n\t\t\t\t<div class=\"elementor-element elementor-element-0668755 e-con e-atomic-element e-flexbox-base e-default-div e-1e8821f\" data-id=\"0668755\" data-element_type=\"e-flexbox\" data-e-type=\"e-flexbox\" data-interaction-id=\"0668755\">\n    <div class=\"elementor-element elementor-element-79a0864 e-con e-atomic-element e-flexbox-base e-default-div e-ebae990\" data-id=\"79a0864\" data-element_type=\"e-flexbox\" data-e-type=\"e-flexbox\" data-interaction-id=\"79a0864\">\n    \t\t\t<img fetchpriority=\"high\" decoding=\"async\" class=\"e-image-base e-default-img e-4ece529-2e5b4af\" data-interaction-id=\"4ece529\" id=\"989\" src=\"https:\/\/powershine-newenergy.com\/wp-content\/uploads\/2026\/10\/US-Standard-Hybrid-Inverter-0-1.png\" width=\"1254\" height=\"1254\" srcset=\"https:\/\/powershine-newenergy.com\/wp-content\/uploads\/2026\/10\/US-Standard-Hybrid-Inverter-0-1.png 1254w, https:\/\/powershine-newenergy.com\/wp-content\/uploads\/2026\/10\/US-Standard-Hybrid-Inverter-0-1-300x300.png 300w, https:\/\/powershine-newenergy.com\/wp-content\/uploads\/2026\/10\/US-Standard-Hybrid-Inverter-0-1-1024x1024.png 1024w, https:\/\/powershine-newenergy.com\/wp-content\/uploads\/2026\/10\/US-Standard-Hybrid-Inverter-0-1-150x150.png 150w, https:\/\/powershine-newenergy.com\/wp-content\/uploads\/2026\/10\/US-Standard-Hybrid-Inverter-0-1-768x768.png 768w\" alt=\"POWERSHINE PS-SI-F-12K-48 12kW US Standard Split-Phase Hybrid Solar Inverter 48V\"\/>\t\t\n<\/div>\n<div class=\"elementor-element elementor-element-4bd30ae e-con e-atomic-element e-flexbox-base e-default-div e-d9a8b61\" data-id=\"4bd30ae\" data-element_type=\"e-flexbox\" data-e-type=\"e-flexbox\" data-interaction-id=\"4bd30ae\">\n    \t\t\t<h2 data-interaction-id=\"6445822\" class=\"e-6445822-d874040 e-heading-base e-default-h2\">US Standard Split-Phase Hybrid Solar Inverter<\/h2>\n\t\t\t\t\t<h3 data-interaction-id=\"b32e445\" class=\"e-b32e445-461fad1 e-heading-base e-default-h3\">12kW | US Standard Split-Phase | 48V DC | PS-SI-F-12K-48<\/h3>\n\t\t\t\t\t<p class=\"e-f0d448b-43ca0f1 e-paragraph-base e-default-p\" data-interaction-id=\"f0d448b\">The POWERSHINE PS-SI-F-12K-48 is a 12kW US Standard split-phase hybrid solar inverter designed for residential solar energy storage and backup power systems. It operates with a 48V battery system.<br><br>Combining solar power, battery storage, and utility power management, this inverter provides a flexible energy solution for residential and off-grid applications.<\/p>\n\t\t\t\t\t<h3 data-interaction-id=\"4257333\" class=\"e-4257333-55a0b3a e-heading-base e-default-h3\">Key Features<\/h3>\n\t\t\t\t\t<p class=\"e-84590bc-b48b75b e-paragraph-base e-default-p\" data-interaction-id=\"84590bc\">\u2022 12kW Rated Output \u2013 Designed for residential energy systems.<br>\u2022 US Standard Split-Phase \u2013 Suitable for 120\/240V residential power applications.<br>\u2022 48V Battery System \u2013 Compatible with 48V battery storage.<br>\u2022 Hybrid Energy Management \u2013 Integrates solar, battery, and utility power.<br>\u2022 Backup Power Supply \u2013 Suitable for residential backup applications.<br>\u2022 Flexible Applications \u2013 Supports residential solar and off-grid energy systems.<\/p>\n\t\t\n<\/div>\n\n<\/div>\n<div class=\"elementor-element elementor-element-d5dd60d e-con e-atomic-element e-flexbox-base e-default-div e-8a5ae70\" data-id=\"d5dd60d\" data-element_type=\"e-flexbox\" data-e-type=\"e-flexbox\" data-interaction-id=\"d5dd60d\">\n    \t\t\t<h2 data-interaction-id=\"f7e4354\" class=\"e-f7e4354-fc1e06b e-heading-base e-default-h2\">Technical Specifications<\/h2>\n\t\t\n<\/div>\n<div data-aos=\"fade-up\" class=\"hostinger-elementor-aos elementor-element elementor-element-9196248 e-flex e-con-boxed e-con e-parent\" data-id=\"9196248\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-15c052e elementor-widget elementor-widget-wp-widget-custom_html\" data-id=\"15c052e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"wp-widget-custom_html.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"textwidget custom-html-widget\">\r\n<div style=\"width:100%;margin:16px 0 24px\">\r\n<table style=\"width:100%;border-collapse:collapse;font-family:Arial,sans-serif;font-size:13px;line-height:1.5;color:#263445\">\r\n<colgroup>\r\n<col style=\"width:54%\">\r\n<col style=\"width:46%\">\r\n<\/colgroup>\r\n<thead>\r\n<tr style=\"background:#173b64;color:#ffffff\">\r\n<th style=\"padding:12px 9px;text-align:left;border:1px solid #dce4ec\">Technical Parameter<\/th>\r\n<th style=\"padding:12px 9px;text-align:left;border:1px solid #dce4ec\">PS-SI-F-12K-48<\/th>\r\n<\/tr>\r\n<\/thead>\r\n<tbody>\r\n<tr style=\"background:#eaf1f8;color:#173b64;font-weight:bold\"><td colspan=\"2\" style=\"padding:10px 9px\">Solar PV Input<\/td><\/tr>\r\n<tr><td style=\"padding:8px;border:1px solid #dce4ec\">Maximum PV Input Power<\/td><td style=\"padding:8px;border:1px solid #dce4ec\">6kW + 6kW<\/td><\/tr>\r\n<tr><td style=\"padding:8px;border:1px solid #dce4ec\">PV Open Circuit Voltage<\/td><td style=\"padding:8px;border:1px solid #dce4ec\">500V DC<\/td><\/tr>\r\n<tr><td style=\"padding:8px;border:1px solid #dce4ec\">MPPT Voltage Range<\/td><td style=\"padding:8px;border:1px solid #dce4ec\">90\u2013450V DC<\/td><\/tr>\r\n<tr><td style=\"padding:8px;border:1px solid #dce4ec\">Maximum PV Input Current<\/td><td style=\"padding:8px;border:1px solid #dce4ec\">22A + 22A<\/td><\/tr>\r\n<tr><td style=\"padding:8px;border:1px solid #dce4ec\">Number of MPPT Trackers<\/td><td style=\"padding:8px;border:1px solid #dce4ec\">2<\/td><\/tr>\r\n\r\n<tr style=\"background:#eaf1f8;color:#173b64;font-weight:bold\"><td colspan=\"2\" style=\"padding:10px 9px\">AC Input<\/td><\/tr>\r\n<tr><td style=\"padding:8px;border:1px solid #dce4ec\">Rated Input Voltage<\/td><td style=\"padding:8px;border:1px solid #dce4ec\">120V AC (L1\/N, L2\/N) \/ 240V AC (L1\/L2)<\/td><\/tr>\r\n<tr><td style=\"padding:8px;border:1px solid #dce4ec\">Input Voltage Range<\/td><td style=\"padding:8px;border:1px solid #dce4ec\">90\u2013140V AC \u00b12%<\/td><\/tr>\r\n<tr><td style=\"padding:8px;border:1px solid #dce4ec\">Input Frequency<\/td><td style=\"padding:8px;border:1px solid #dce4ec\">50Hz \/ 60Hz (Auto Detection)<\/td><\/tr>\r\n<tr><td style=\"padding:8px;border:1px solid #dce4ec\">Maximum Bypass Input Current<\/td><td style=\"padding:8px;border:1px solid #dce4ec\">2-Pole, 40A \/ 40A (L1\/L2)<\/td><\/tr>\r\n<tr><td style=\"padding:8px;border:1px solid #dce4ec\">Maximum Parallel Quantity<\/td><td style=\"padding:8px;border:1px solid #dce4ec\">6 Units<\/td><\/tr>\r\n\r\n<tr style=\"background:#eaf1f8;color:#173b64;font-weight:bold\"><td colspan=\"2\" style=\"padding:10px 9px\">AC Output<\/td><\/tr>\r\n<tr><td style=\"padding:8px;border:1px solid #dce4ec\">Rated Output Power<\/td><td style=\"padding:8px;border:1px solid #dce4ec\">Split-Phase: 12kW; Single-Phase: 7.2kW<\/td><\/tr>\r\n<tr><td style=\"padding:8px;border:1px solid #dce4ec\">Output Voltage<\/td><td style=\"padding:8px;border:1px solid #dce4ec\">120V AC (L1\/N, L2\/N) \/ 240V AC (L1\/L2)<\/td><\/tr>\r\n<tr><td style=\"padding:8px;border:1px solid #dce4ec\">Output Frequency<\/td><td style=\"padding:8px;border:1px solid #dce4ec\">50\/60Hz \u00b10.3Hz<\/td><\/tr>\r\n<tr><td style=\"padding:8px;border:1px solid #dce4ec\">Output Waveform<\/td><td style=\"padding:8px;border:1px solid #dce4ec\">Pure Sine Wave<\/td><\/tr>\r\n<tr><td style=\"padding:8px;border:1px solid #dce4ec\">Motor Load Performance<\/td><td style=\"padding:8px;border:1px solid #dce4ec\">6HP<\/td><\/tr>\r\n<tr><td style=\"padding:8px;border:1px solid #dce4ec\">Battery Mode Overload Capacity<\/td><td style=\"padding:8px;border:1px solid #dce4ec\">5 min at 102\u2013110% load; 10 sec at 110\u2013125% load; 5 sec at &gt;125% load<\/td><\/tr>\r\n<tr><td style=\"padding:8px;border:1px solid #dce4ec\">Maximum Battery Mode Efficiency<\/td><td style=\"padding:8px;border:1px solid #dce4ec\">91%<\/td><\/tr>\r\n<tr><td style=\"padding:8px;border:1px solid #dce4ec\">UPS Transfer Time<\/td><td style=\"padding:8px;border:1px solid #dce4ec\">&lt;10ms<\/td><\/tr>\r\n\r\n<tr style=\"background:#eaf1f8;color:#173b64;font-weight:bold\"><td colspan=\"2\" style=\"padding:10px 9px\">Battery &amp; Charging<\/td><\/tr>\r\n<tr><td style=\"padding:8px;border:1px solid #dce4ec\">Nominal Battery Voltage<\/td><td style=\"padding:8px;border:1px solid #dce4ec\">48V DC<\/td><\/tr>\r\n<tr><td style=\"padding:8px;border:1px solid #dce4ec\">Maximum AC Charging Current<\/td><td style=\"padding:8px;border:1px solid #dce4ec\">160A<\/td><\/tr>\r\n<tr><td style=\"padding:8px;border:1px solid #dce4ec\">Maximum PV Charging Current<\/td><td style=\"padding:8px;border:1px solid #dce4ec\">220A<\/td><\/tr>\r\n<tr><td style=\"padding:8px;border:1px solid #dce4ec\">Maximum Charging Current (PV + AC)<\/td><td style=\"padding:8px;border:1px solid #dce4ec\">220A<\/td><\/tr>\r\n<tr><td style=\"padding:8px;border:1px solid #dce4ec\">Operating Battery Voltage Range<\/td><td style=\"padding:8px;border:1px solid #dce4ec\">43.2\u201358.4V DC<\/td><\/tr>\r\n\r\n<tr style=\"background:#eaf1f8;color:#173b64;font-weight:bold\"><td colspan=\"2\" style=\"padding:10px 9px\">General Specifications<\/td><\/tr>\r\n<tr><td style=\"padding:8px;border:1px solid #dce4ec\">Display<\/td><td style=\"padding:8px;border:1px solid #dce4ec\">LCD<\/td><\/tr>\r\n<tr><td style=\"padding:8px;border:1px solid #dce4ec\">Communication Interfaces<\/td><td style=\"padding:8px;border:1px solid #dce4ec\">USB \/ RS485 \/ WiFi \/ GPRS \/ Dry Contact Control<\/td><\/tr>\r\n<tr><td style=\"padding:8px;border:1px solid #dce4ec\">Monitoring<\/td><td style=\"padding:8px;border:1px solid #dce4ec\">WiFi<\/td><\/tr>\r\n<tr><td style=\"padding:8px;border:1px solid #dce4ec\">Ingress Protection<\/td><td style=\"padding:8px;border:1px solid #dce4ec\">IP20<\/td><\/tr>\r\n<tr><td style=\"padding:8px;border:1px solid #dce4ec\">Operating Temperature<\/td><td style=\"padding:8px;border:1px solid #dce4ec\">-10\u00b0C to +55\u00b0C<\/td><\/tr>\r\n<tr><td style=\"padding:8px;border:1px solid #dce4ec\">Relative Humidity<\/td><td style=\"padding:8px;border:1px solid #dce4ec\">5\u201395% (Non-Condensing)<\/td><\/tr>\r\n<tr><td style=\"padding:8px;border:1px solid #dce4ec\">Maximum Operating Altitude<\/td><td style=\"padding:8px;border:1px solid #dce4ec\">4,000m (Derating Above 2,000m)<\/td><\/tr>\r\n\r\n<tr style=\"background:#eaf1f8;color:#173b64;font-weight:bold\"><td colspan=\"2\" style=\"padding:10px 9px\">Dimensions &amp; Weight<\/td><\/tr>\r\n<tr><td style=\"padding:8px;border:1px solid #dce4ec\">Product Dimensions (L \u00d7 W \u00d7 H)<\/td><td style=\"padding:8px;border:1px solid #dce4ec\">600 \u00d7 450 \u00d7 140mm<\/td><\/tr>\r\n<tr><td style=\"padding:8px;border:1px solid #dce4ec\">Package Dimensions (L \u00d7 W \u00d7 H)<\/td><td style=\"padding:8px;border:1px solid #dce4ec\">660 \u00d7 510 \u00d7 200mm<\/td><\/tr>\r\n<tr><td style=\"padding:8px;border:1px solid #dce4ec\">Net Weight<\/td><td style=\"padding:8px;border:1px solid #dce4ec\">23.3kg<\/td><\/tr>\r\n<tr><td style=\"padding:8px;border:1px solid #dce4ec\">Gross Weight<\/td><td style=\"padding:8px;border:1px solid #dce4ec\">25kg<\/td><\/tr>\r\n<\/tbody>\r\n<\/table>\r\n<\/div>\r\n<\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<h2 data-interaction-id=\"5d709f3\" class=\"e-5d709f3-f57991f e-heading-base e-default-h2\">Applications<\/h2>\n\t\t\t\t\t<p class=\"e-paragraph-base e-default-p\" data-interaction-id=\"88526e3\">\u2022 Residential Solar Systems \u2013 120\/240V split-phase power applications.<br>\u2022 Home Energy Storage \u2013 Integration with 48V battery systems.<br>\u2022 Whole-Home Backup \u2013 Backup power for residential electrical loads.<br>\u2022 Off-Grid Power Systems \u2013 Solar and battery-powered residential applications.<br>\u2022 Hybrid Solar Applications \u2013 Flexible solar, battery, and utility power management.<\/p>\n\t\t\t\t\t<h2 data-interaction-id=\"3402823\" class=\"e-3402823-6f6d1c6 e-heading-base e-default-h2\">Solicitar cotizaci\u00f3n<\/h2>\n\t\t\t\t\t<p class=\"e-paragraph-base e-default-p\" data-interaction-id=\"a62c39b\">Interested in the POWERSHINE PS-SI-F-12K-48 12kW US Standard Split-Phase Hybrid Solar Inverter?<br>Contact us for factory pricing, detailed specifications, and OEM\/ODM cooperation.<\/p>\n\t\t<div data-aos=\"fade-up\" class=\"hostinger-elementor-aos elementor-element elementor-element-0fb610e e-con-full e-flex e-con e-child\" data-id=\"0fb610e\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-4df4699 elementor-widget elementor-widget-button\" data-id=\"4df4699\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"mailto:marketing@szpowershine.com?subject=Inquiry%20for%20PS-SI-F-12K-48%2012kW%20US%20Standard%20Split-Phase%20Hybrid%20Solar%20Inverter\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Email Inquiry<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e1ef2e7 elementor-widget elementor-widget-button\" data-id=\"e1ef2e7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t\t\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"https:\/\/wa.me\/8618676755973?text=Hello%20POWERSHINE%2C%20I%20am%20interested%20in%20PS-SI-F-12K-48%2012kW%20US%20Standard%20Split-Phase%20Hybrid%20Solar%20Inverter.%20Please%20send%20me%20your%20factory%20pricing%20and%20technical%20specifications.\" target=\"_blank\" rel=\"noopener\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">WhatsApp Inquiry<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>US Standard Split-Phase Hybrid Solar Inverter 12kW | US Standard Split-Phase | 48V DC | PS-SI-F-12K-48 The POWERSHINE PS-SI-F-12K-48 is a 12kW US Standard split-phase hybrid solar inverter designed for residential solar energy storage and backup power systems. It operates with a 48V battery system. Combining solar power, battery storage, and utility power management, this [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-1541","page","type-page","status-publish","hentry"],"_hostinger_reach_plugin_has_subscription_block":false,"_hostinger_reach_plugin_is_elementor":false,"_links":{"self":[{"href":"https:\/\/powershine-newenergy.com\/es\/wp-json\/wp\/v2\/pages\/1541","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/powershine-newenergy.com\/es\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/powershine-newenergy.com\/es\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/powershine-newenergy.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/powershine-newenergy.com\/es\/wp-json\/wp\/v2\/comments?post=1541"}],"version-history":[{"count":4,"href":"https:\/\/powershine-newenergy.com\/es\/wp-json\/wp\/v2\/pages\/1541\/revisions"}],"predecessor-version":[{"id":1545,"href":"https:\/\/powershine-newenergy.com\/es\/wp-json\/wp\/v2\/pages\/1541\/revisions\/1545"}],"wp:attachment":[{"href":"https:\/\/powershine-newenergy.com\/es\/wp-json\/wp\/v2\/media?parent=1541"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}